37- Six Digital Retainers Compared for Strength and Stability

Show notes

Comparison of Retainers:

  • Study: Tested 6 CAD-CAM retainers vs. traditional stainless steel.
  • Simulated Use: 15 years, 1.2 million chewing cycles.

Key Findings:

  • Stainless Steel Twist-Flex: Did not fail, highest load capacity (445 N).
  • Titanium Grade 5: Only CAD-CAM option matching strength.
  • Others (Nickel-Titanium, Zirconia, Gold, Cobalt-Chromium, P.E.K.): Premature breakage or debonding.

Conclusion: Stainless steel remains the gold standard for long-term retention.

…………………….

Take Your Practice to the Next Level!

Feeling overwhelmed trying to figure out how to optimize your practice, choose the right tools, and actually implement them day-to-day? You’re not alone – and you don’t have to do it all on your own!

If you want to deepen your understanding and expand your skillset step by step, the Lean Orthodontics book series offers structured insights and practical strategies you can apply immediately in your daily workflow

And if you would like personal 1:1 guidance while implementing these ideas in your own practice:

Here’s the deal: You’ve got the drive, and I’ve got the expertise to guide you. Let’s work together to unlock your practice’s full potential.

🎯 Book your free consultation call now. Let’s make it happen!

– Dr. Dr. Martin Baxmann

Show transcript

00:00:00: Today, we're testing six modern CAD-CAM retainers against the classic stainless steel version to see which one lasts longer and holds teeth more stable.

00:00:11: Let's find out whether technology has truly replaced tradition when it comes to orthodontic retention!

00:00:31: The researcher simulated fifteen years of wear, one point two million chewing cycles under standardized conditions and then tested how much force each retainer could withstand before failure.

00:00:44: The results were striking!

00:00:46: The conventional stainless steel twist flex did not fail once.

00:00:51: it also showed the highest load capacity around four hundred forty five newtons which is well above normal incisal bite forces.

00:01:01: Among all CAD-CAM options, only titanium grade five retainers survived the entire test and reached comparable strength levels.

00:01:12: Every other digital retainer type – nickel titanium, zirconia gold cobalt chromium & PEK showed either premature breakage or debonding.

00:01:24: especially PEK failed completely Neatly fractured frequently, and because of its elasticity those fractures could remain invisible until relapse occurs.

00:01:36: From a clinical point-of view this means that twist flex remains the gold standard.

00:01:42: Titanium grade the fifth may become good alternative but others are not mechanically sufficient for long term use.

00:01:50: The authors model was highly standardized and realistic, but we must remember it is still an in vitro simulation.

00:01:57: Real mouths are more complex!

00:02:00: So until further long term clinical data exist I would advise staying with what works.

00:02:07: a hand-bend multi stranded steel retainer properly bonded and monitored continues to offer the most reliable long-term retention we have.

00:02:16: Thanks for watching!

00:02:17: I'm Dr.

00:02:18: Martin Baxman, let's bring science back.